Hybrid/EV Battery Voltage Sense U Circuit High
P0BA2 flags an excessive voltage on channel U. GM's eAssist mild hybrid uses the lowest threshold of the documented systems: above 4.65 V in 7 of 10 samples with the 12 V supply above 8.8 V, Type B. The 2016 Volt and the 2019 battery controller set it at 4.8 V or more held for 1.4 s within 2 s, Type A; the 16OBDG02 programme at above 4.90 V in 14 of 18 samples, Type A. As with the low code, the high test is held back while an open sense line or module communication fault is active. Channel U does not exist on the twenty-block two-mode trucks. Before replacing parts, the actual cell voltage should be measured, because a lead touching a higher potential is far more common than a real overcharge.
Possible causes
- Sense lead U in contact with a higher potential high
- Measuring IC misreading channel U medium
- Cell U actually overcharged low
Symptoms
- MIL and hybrid or EV warning
- Charging stopped early
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0BA2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?