P0B9A
Hybrid/EV Battery Voltage Sense T Circuit
P0B9A is the open-circuit code for sense T, the twentieth cell channel. GM uses it only on lithium-ion packs. The 2011 Volt compares adjacent cells for a difference above 1 V and checks the busbar cap voltage against 0.7 V; the 2016 Volt and ELR raise the adjacent-cell limit to 1.3 V, add a balancing-gate test below 36 mV and decide within 0.6 s, and the 2019 controller keeps those values but stretches the window to 0.8 s of 1.6 s, Type A in both cases. The 2012 two-mode trucks also have a channel T, their last nickel-metal hydride block 20, yet their tables carry range, low and high codes for it and no circuit code. A genuinely open lead usually means opening the high-voltage pack.
Possible causes
- Open sense lead T at the cell tab or connector high
- Poor busbar or splice joint in the channel T path medium
- Monitoring board input for channel T failed low
Symptoms
- MIL, hybrid or EV system warning
- Ready mode or charging blocked
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B9A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.