P0B89
Hybrid/EV Battery Voltage Sense P Circuit High
P0B89 covers the opposite case to P0B88: the voltage reported on channel P is above the plausible range. GM's 2012 two-mode hybrids assign P to NiMH block 16 and set the code when the block exceeds 23 V in 15 of 20 samples at 100 ms, Type B, provided no battery controller fault P0A1F is active. In lithium-ion systems GM sets 4.8 V or more for 1.4 s in 2 s as the limit, Type A, while the BAS Plus mild hybrid reacts above 4.65 V. GM's 2016 program with a separate sense module allows up to 4.90 V. Overcharging is unlikely to be the cause because the controller stops charging well below these values; a sense lead reaching a higher tap or an input fault is the usual explanation. Expect restricted charging.
Possible causes
- Lead P in contact with a higher cell tap high
- Input fault in the cell monitoring electronics medium
- Genuine overvoltage of the cell or block low
Symptoms
- Charging restricted
- MIL and hybrid warning
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B89
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.