P0B77
Hybrid/EV Battery Voltage Sense M Circuit
P0B77 flags an open or high-resistance tap on voltage sense M, the thirteenth cell channel. GM's 2019 battery energy control module checks seven cases: adjacent cells differing by 1.3 V or more, a balancing gate reading below 36 mV, or splice voltages above 0.1 V (0.5 V at a busbar splice). M is the last channel there with the short 0.6 s window, Type A. The BAS Plus mild hybrid instead needs lines N and N-1 both below 1.4 V plus a jump over 0.5 V within 200 ms, 7 of 10 samples, Type B. Ford's TSB 23-2039 names P0B77 for 2019-2020 Fusion plug-in hybrids that no longer start and prescribes a new traction battery. Range, low and high faults on M carry their own codes.
Possible causes
- Open or corroded tap of sense lead M at the cell connector high
- Fault inside the traction battery (Ford Fusion PHEV TSB 23-2039) medium
- High resistance at a splice or busbar joint in the sense path medium
- Defective cell monitoring board input low
Symptoms
- MIL with hybrid or EV system warning
- Vehicle may not start or go into ready mode
- Charging blocked or limited
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B77
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.