P0B72
Hybrid/EV Battery Voltage Sense L Circuit
P0B72 reports an open circuit on voltage sense L, the twelfth channel. One detail sets it apart from its neighbours: GM's 2011 hybrid tables list every open sense line code from P0B3B upward except P0B72 (and P0B90), so the early system did not use it, while L's range, low and high codes were present. Later GM tables include it. The BAS Plus mild hybrid sets it when lines N and N-1 fall below 1.4 V with a change above 0.5 V in 200 ms, 7 of 10 samples, Type B; the 2019 battery energy control module uses its adjacent-cell, balancing and splice tests within 0.6 s, Type A. Ford's Fusion plug-in hybrid bulletin for 2019-2020 includes P0B72 and replaces the traction battery.
Possible causes
- Open sense lead, crimp or cell tap on channel L high
- Internal traction battery failure, pack replacement (Ford Fusion PHEV) medium
- High-resistance splice or bus bar joint low
Symptoms
- No start or no ready mode
- Battery or hybrid system warning
- Charging aborted
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B72
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.