P0B65
Hybrid/EV Battery Voltage Sense I Circuit Low
The 2012 GM two-mode hybrids show a detail worth knowing for P0B65: their battery pack control module only declares channel I, nickel-metal hydride block 9, too low when block 9 and its neighbour block 10 both read under 2 V, and only after 15 of 20 samples at 100 ms; the fault is Type B and needs two trips. A single weak block alone therefore does not set it. GM's lithium-ion controllers judge each cell on its own, setting P0B65 at 0.2 V or less held for 1.4 s within 2 s, Type A, as long as no open-line or communication fault has priority. The BAS Plus mild hybrid uses 1.4 V and 7 of 10 samples. In all cases the reading is too low to be a real cell.
Possible causes
- Channel I sense lead shorted to ground or a lower tap high
- Connector fault affecting adjacent blocks 9 and 10 (two-mode) medium
- Failed measuring input in the battery controller low
Symptoms
- Hybrid system warning and MIL
- Engine runs more often, electric assist reduced
- Limited power in limp mode
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B65
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.