P0B61
Hybrid/EV Battery Voltage Sense H Circuit High
A lithium-ion cell cannot sit much above about 4.2 V, so when channel H reads 4.8 V or more the GM battery energy control module concludes the sense circuit is wrong and stores P0B61 after 1.4 s within a 2 s window, Type A. GM's BAS Plus mild hybrid sets the same code at more than 4.65 V on the cell sense line in 7 of 10 samples, Type B, while the 2012 two-mode hybrids treat H as nickel-metal hydride block 8 and only object above 23 V in 15 of 20 samples, Type B. A high reading usually comes from a sense lead touching a higher potential or from a monitoring input that floats when a reference connection is lost. Unlike P0B60 the controller here suspects overvoltage, so charging is typically blocked.
Possible causes
- Channel H sense lead in contact with a higher cell tap high
- Lost reference connection letting the measuring input float medium
- Internal fault of the cell monitoring chip low
Symptoms
- Charging refused or stopped early
- MIL with reduced electric power
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B61
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.