P0B60
Hybrid/EV Battery Voltage Sense H Circuit Low
P0B60 means channel H reports less voltage than any healthy cell or block could hold, so the measurement itself is suspect. GM publishes three variants. Lithium-ion packs with a battery energy control module (2016 and 2019 tables) trip at 0.2 V or less for 1.4 s inside a 2 s window, Type A, provided no open-line, communication or balancing fault is already stored. The BAS Plus mild hybrid in table 13OBDG05C uses a cell sense line threshold of 1.4 V and needs 7 failures out of 10, Type B. The 2012 two-mode trucks compare blocks 8 and 9, both under 2 V in 15 of 20 samples, Type B. Typical culprits are a sense lead shorted to ground or a failed input on the monitoring board.
Possible causes
- Channel H sense lead shorted to ground or to the next lower tap high
- Failed measuring input on the cell monitoring board medium
- Cell or block on channel H actually collapsed low
Symptoms
- MIL and hybrid or EV system warning
- Electric drive power limited or switched off
- Charging interrupted
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended