P0B5C
Hybrid/EV Battery Voltage Sense G Circuit High
P0B5C marks an out-of-range high reading on cell sense channel G. For a technician the quickest plausibility check is arithmetic: the sum of all cell or block readings should match the pack voltage, so a single channel that reads far too high while the total stays normal is a sensing fault. GM formalises the limits as 4.8 V or more for 1.4 s within 2 s in the battery energy control module of its lithium-ion systems, Type A, one trip, and as more than 23 V for block 7 of the 2012 two-mode trucks and SUVs, 15 of 20 samples, Type B, two trips. Overcharged cells are flagged by other codes. Until the fault is fixed, battery power and charging are limited.
Possible causes
- Channel G sense lead touching a higher cell tap high
- Faulty measuring input or reference in the module medium
- Contamination or moisture on the monitoring board low
Symptoms
- MIL and hybrid or EV warning
- Charging limited or refused
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B5C
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?