P0B4D
Hybrid/EV Battery Voltage Sense D Circuit High
P0B4D sets when cell sense channel D reports more voltage than the cell or block behind it can deliver. GM's limits are 4.8 V or more for 1.4 s within 2 s on lithium-ion packs (battery energy control module, Type A, one trip) and above 23 V for block 4 of the 2012 two-mode hybrids (15 of 20 samples, Type B, two trips). A practical first check is live data: if channel D sits far above its neighbours while the pack voltage and the other channels look normal, the fault is in the sense path, not in the cells. Typical findings are a sense lead that contacts a higher tap or a damaged measuring input. The controller limits power until the code is repaired.
Possible causes
- Channel D sense lead contacting a tap of higher potential high
- Damaged measuring input in the monitoring electronics medium
- Moisture or contamination on the monitoring board creating leakage paths low
Symptoms
- MIL and battery system warning
- Reduced acceleration and regenerative braking
- Charging power limited or charging refused
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended