P0B43
Hybrid/EV Battery Voltage Sense B Circuit High
P0B43 sets when cell voltage channel B reads higher than a lithium-ion cell can physically reach in service, so the controller blames the measurement path. GM documents the criteria for its battery energy control module: cell voltage B at 4.8 V or above for 1.4 s within a 2 s window, Type A, one trip, with open sense line, communication and balancing faults ruled out first. Beyond GM, no manufacturer documents P0B43 publicly; FCA's sister code P0B3E for channel A shows that software in the battery controller can cause such readings. CARB treats battery voltage sensors as monitored input components. Overcharged cells use separate cell voltage codes. Low, range and open faults of channel B are P0B42, P0B41 and P0B40.
Possible causes
- Open sense line letting the input float high high
- Battery controller software misreading the channel medium
- Measurement input of the cell monitoring chip failed low
Symptoms
- MIL and hybrid warning on
- Charging or electric drive limited
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B43
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.