P0B35
High Voltage Service Disconnect Circuit Low
P0B35 sets when the service disconnect detection signal stays below its lower limit. Where the loop is coded with a resistor in the plug, as in a Lear patent, a reading near zero typically points to a short to ground in the loop wiring; the exact meaning depends on how the manufacturer powers the input. Ford traced an intermittent short to ground in the low-voltage interlock wiring as the cause of its open-loop code P0B37 on the C-Max Energi, which shows how chafed harnesses act here. No manufacturer documents P0B35 publicly. CARB treats such signals as monitored hybrid inputs. High, open and performance faults are P0B36, P0B37 and P0B34. The contactors usually stay open.
Possible causes
- Detection loop wire chafed and shorted to ground high
- Moisture or corrosion in the plug base bridging to ground medium
- Coding element in the plug shorted low
- Battery controller input stage fault low
Symptoms
- No ready mode or stall with a stop-safely message
- MIL and high-voltage warning on
- Charging not possible
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B35
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.