Powertrain
generic / SAE
P0B32
Hybrid/EV Battery D Voltage High
The voltage of HV battery D exceeds the expected window. Charging overvoltage or sense fault. Cell-group voltage monitoring is the foundation of HV battery safety — drift here triggers contactor opening, charge inhibit, and reduced power to protect the pack.
SystemPowertrain
Typegeneric / SAE
GroupP0
Range / numberB / 32
Possible causes
- Charging system overvoltage high
- Sense circuit drifted high medium
- Pack cell imbalance approaching service threshold low
Symptoms
- EV/hybrid system warning light on
- Reduced power output or limp mode
- Charging may fail or be slowed
- Reduced electric range
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
- Estimated cost: 500–5000 €
- Estimated time: 3–16 h
- Component: hv battery d
- Component: bms
- MIL / check engine light
- limp mode possible
Sources
References
sae:J2012