P0B2A
Hybrid/EV Battery B Voltage High
P0B2A is stored when the voltage of hybrid/EV battery B rises above its permitted upper limit. It mirrors P0B29 (too low), while P0B28 covers fluctuation and P0B27 the general fault. No manufacturer explains P0B2A publicly; the closest documented case is Bentley's P0B26 for battery A, where a failing 48 V super capacitor reads too high. GM's analogous whole-pack overvoltage monitor is P0ABD (above 479 V, Type A). CARB demands monitoring of battery voltage sensors and cells in hybrid storage systems. Likely causes are a cell group charged too high because balancing fails, or a measuring fault. To protect the cells the controller restricts charging and recuperation and may open the contactors.
Possible causes
- Cell group in battery B charged too high, balancing ineffective medium
- Voltage measurement fault in the controller or sense leads medium
- Battery controller software fault low
Symptoms
- Hybrid/EV system or high-voltage battery warning on
- MIL on
- Charging or recuperation restricted
- Battery power limited, less electric drive or assist
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B2A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.