P0B1F
Hybrid/EV Battery Pack Voltage Sense D Circuit Range/Performance
P0B1F says pack voltage measurement D is electrically present but disagrees with what the controller expects, typically the sum of cell voltages or a parallel pack measurement. It is a plausibility fault, not an open or shorted circuit. No manufacturer documents P0B1F publicly. GM's analogous channel A check, P0ABB, fails at a deviation above 12 V from the summed cell voltages for 20 of 25 samples at 25 ms, Type A, one trip. CARB requires rationality checks for battery voltage sensors of hybrid storage systems. Circuit faults of channel D use P0B1E, P0B20 and P0B21. With a doubtful pack voltage the controller narrows the usable battery window and limits power.
Possible causes
- Drift or calibration error of measurement channel D high
- Cell voltage acquisition faulty, reference sum wrong medium
- Increased resistance at sense terminals medium
- Battery controller software needs an update low
Symptoms
- MIL and hybrid/EV system warning on
- Implausible state-of-charge or range display
- Battery power limited, reduced electric drive or assist
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended