SAE J2012 reserves up to four pack voltage measurements, A to D; voltage sense B is the second one. P0B14 is its general circuit code: the battery controller sees an electrical fault on this input, typically an open or implausible raw signal. Which tap a manufacturer calls B is not standardised. No manufacturer documents P0B14 publicly. For the comparable channel A GM checks pack-side voltage against fixed limits and against the sum of cell voltages (P0ABB to P0ABD). CARB requires battery voltage sensors of hybrid storage systems to be monitored like any input component. Range, low, high and erratic faults have their own codes, P0B15 to P0B18. The system usually limits or blocks high-voltage operation.
Possible causes
- Voltage sense lead or its fuse open inside the pack high
- Sense connector at the battery controller loose or corroded medium
- Measurement input of the battery controller defective medium
Symptoms
- MIL and hybrid/EV system warning on
- Battery power limited, reduced electric drive or assist
- Vehicle may not reach Ready or may shut down the high-voltage system
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0B14
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)