P0AE7
Hybrid/EV Battery Precharge Contactor A Control Circuit High
P0AE7 is stored when the control line of precharge contactor A carries too much voltage for its commanded state, typically a short to the 12 V supply. In GM's 2016 and 2019 hybrid tables the high-side driver output reads between 5.27 and 19.7 V while the contactor is commanded off, 40 of 50 samples at 12.5 ms, Type B, two trips. GM's 2013 eAssist controller looks for a short to power on its low-side driver in the on state, 3 of 5 samples at 50 ms, Type B. A coil energized by a short may keep the precharge path closed when it should be open, so P0AE2 can follow. CARB requires circuit monitoring of such hybrid outputs. The negative and positive main contactor counterparts are P0AE0 and P0ADC.
Possible causes
- Control wire shorted to 12 V supply high
- Driver stage stuck on in the battery controller medium
- Outdated battery controller calibration low
Symptoms
- Vehicle may not start or become ready
- MIL and hybrid warning on
- Possible additional stuck-closed code P0AE2
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0AE7
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.