P0AE6
Hybrid/EV Battery Precharge Contactor A Control Circuit Low
P0AE6 means the control line of precharge contactor A is pulled too low, usually a short to ground. GM documents it in several programs. The 2016 and 2019 hybrid tables test the high-side driver while the contactor is commanded on and fail it below 5.35 V, 13 of 16 samples at 12.5 ms, Type B with two trips, enabled above 10.2 V system voltage. GM's 2013 eAssist battery controller uses a low-side driver and flags low voltage in the off state, which there points to a short to ground or an open circuit, 3 of 5 samples at 50 ms, Type B. CARB requires such circuit checks on hybrid outputs. Because the coil cannot pull in, precharge never starts; the positive main contactor equivalent is P0ADB.
Possible causes
- Control wire chafed and shorted to ground high
- Precharge contactor coil shorted internally medium
- Open circuit on low-side driven designs (GM eAssist) low
- Driver stage in the battery controller defective low
Symptoms
- Vehicle does not become ready to drive
- MIL and hybrid warning on
- Engine start or electric drive unavailable
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended