P0AE4
Hybrid/EV Battery Precharge Contactor A Control Circuit/Open
P0AE4 concerns the circuit that drives the coil of precharge contactor A, not its contacts. GM uses it in many hybrid and EV tables, with changing logic: the 2016 and 2019 OBDG02 tables look for an open high-side driver circuit, a control voltage between 1.15 and 2.81 V while commanded off, 40 of 50 samples at 12.5 ms, Type B, two trips. The 2019 OBDG01 version also catches a short to power while off and a coil current below 194 mA while on. The 2011 Volt table instead flags a short to battery voltage in the off state, Type A, one trip. With the coil not driven, precharge cannot start and the high-voltage system stays off. Low and high variants are P0AE6 and P0AE7.
Possible causes
- Open control wire or loose connector at the contactor coil high
- Precharge contactor coil open internally medium
- Control wire shorted to 12 V (GM 2011 and 2019 logic) low
- Driver stage in the battery or hybrid controller defective low
Symptoms
- Vehicle does not become ready to drive
- MIL and hybrid or EV warning on
- Charging not possible
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0AE4
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.