P0AE3
Hybrid/EV Battery Precharge Contactor Circuit Stuck Open
P0AE3 is set when the precharge path does not conduct after it has been commanded closed, so the bus voltage fails to rise and the main contactors are not allowed to close. GM documents several cases: preliminary information PIC6165A for the 2016-17 Chevrolet Volt describes a rare P0AE3 in cool weather right after a completed charge, without driveability effects; parts should not be replaced, a new calibration followed, and the MIL goes out after three clean drive cycles. GM bulletin 23-NA-151 lists P0AE3 among high-priority codes on Ultium EVs that call for battery stability checks. Audi includes P0AE300 for the 2022 e-tron GT. Unlike P0AE2, the contacts stay open; a slow precharge is P0C78.
Possible causes
- Battery controller calibration sets the code under certain conditions (GM Volt, Audi) high
- Precharge contactor contacts burnt or coil not pulling in medium
- Precharge resistor or its fuse open medium
- Internal fault in the battery disconnect unit low
Symptoms
- Vehicle does not become ready to drive
- MIL or service engine soon light on
- No battery charge level shown after switching on
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0AE3
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?