P0AE0
Hybrid/EV Battery Negative Contactor Control Circuit High
P0AE0 is stored when the negative contactor drive circuit shows too high a voltage for its state, which mostly means a short to battery voltage. GM's 2016-19 hybrid tables set it with the contactor commanded off and the driver output between 5.27 and 19.7 V for 40 of 50 samples at 12.5 ms, Type B, two trips. CARB 1968.2 requires hybrid output components to be monitored for such circuit faults. Siblings are P0ADD (open) and P0ADF (low); the positive side equivalent is P0ADC. A coil energized by a short could keep the contactor closed, so a stuck-closed code P0AA4 may follow. The controller usually disables the high-voltage system.
Possible causes
- Coil control wire shorted to 12 V high
- Damaged harness or connector at the battery disconnect unit medium
- Driver stage in the battery controller shorted low
Symptoms
- Hybrid or EV warning light
- High-voltage system disabled, vehicle not ready
- Possible additional stuck-closed code
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0AE0
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?