P0ADB
Hybrid/EV Battery Positive Contactor Control Circuit Low
P0ADB means the drive circuit of the positive main contactor reads too low, mostly a short to ground. GM uses it widely: 2016-19 tables set it when the control voltage stays under 5.35 V with the contactor commanded on, 13 of 16 samples, Type B. The 2013 eAssist battery controller checks the low-side driver in the off state for a short to ground or an open circuit, 3 of 5 samples, two trips. Audi lists P0ADB00 in battery management 2 (J1120) of 2019-22 A6 to Q8 models with a software fix (TSB 2066205), and Dodge names it for the 2024 Charger EV (TSB 08-071-25). The battery then cannot be connected, so the vehicle will not become ready.
Possible causes
- Coil control wire shorted to ground high
- Contactor coil internally shorted medium
- Battery controller software sets the code (Audi, Dodge bulletins) medium
- Driver stage in the battery controller defective low
Symptoms
- Vehicle does not start; multiple warnings in the cluster
- Hybrid or EV warning light
- Charging not possible
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0ADB
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?