P0AD9
Hybrid/EV Battery Positive Contactor Control Circuit/Open
The positive main contactor connects the traction battery to the high-voltage bus; its coil is driven by the battery or hybrid controller. P0AD9 covers an open in this coil circuit. GM documents it in detail: in hybrid tables from model year 2011 the HPC2 sets it on open load during the commanded state, Type B. 2016-19 tables use a control voltage between 1.15 and 2.81 V with the contactor commanded off, 40 of 50 samples at 12.5 ms; 2019 versions also check coil current below 194 mA when on. CARB requires circuit monitoring of hybrid outputs. Low and high faults are P0ADB and P0ADC; a contactor stuck open is P0AA2. The car usually cannot go ready.
Possible causes
- Open in the contactor coil or its pigtail inside the battery disconnect unit high
- Loose or corroded low-voltage connector at the battery disconnect unit medium
- Broken control wire in the battery harness medium
- High-side driver in the battery controller defective low
Symptoms
- Vehicle will not enter ready mode or start
- Hybrid or EV warning light and check engine light
- Charging not possible
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended