P0AD3
Hybrid/EV Battery Pack Cooling Fan 3 Control Circuit High
With P0AD3 the battery controller finds the control line of cooling fan 3 at a voltage that is too high for the commanded state, pointing to a short to a supply voltage or a fan input that no longer pulls the line down. No manufacturer publicly documents this code; GM's analogous fan 1 code P0A85 trips when the control voltage exceeds 9 V while the fan is driven, Type B. Siblings: P0AD2 for the low side, P0ACF for an open line, P0AD1 if the fan keeps running. CARB 1968.2 calls for this circuit monitoring on battery thermal management parts. Depending on the fault the fan runs permanently or not at all, and the pack may be derated.
Possible causes
- Control wire shorted to 12 V or another supply high
- Fan electronics no longer loading the control line medium
- Bent or bridged pins in the fan connector medium
- Battery controller output stage defective low
Symptoms
- Hybrid or EV system warning light
- Fan 3 runs constantly or not at all
- Reduced electric power when the battery is warm
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0AD3
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.