P0AD2
Hybrid/EV Battery Pack Cooling Fan 3 Control Circuit Low
P0AD2 reports that the control signal for battery fan 3 is pulled too low, typically a short to ground on the line between battery controller and blower. Such fans are mostly speed-controlled by a PWM duty cycle, as a Toyota patent on battery fan control explains. No manufacturer publicly documents P0AD2; GM sets the analogous fan 1 code P0A84 when the control voltage stays below 0.257 V with system voltage above 9.1 V, Type B with two trips. The open circuit is P0ACF, a short to voltage P0AD3. CARB requires these electrical checks for battery thermal components. Fan 3 then cannot be driven, and the battery may run warm with limited power.
Possible causes
- Control wire chafed through to body ground high
- Internal short in fan 3 motor or its electronics medium
- Moisture or spilled liquid in the fan connector medium
- Output stage in the battery controller defective low
Symptoms
- Hybrid or EV system warning light, often with check engine light
- Electric drive power reduced when the battery gets warm
- No fan noise from the battery area when cooling is expected
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0AD2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.