P0AD1
Hybrid/EV Battery Pack Cooling Fan 3 Stuck On
P0AD1 is the counterpart to P0AD0: fan 3 of the traction battery keeps turning although the controller has switched it off or commanded a lower level. A speed feedback or the current in the fan circuit shows that the blower still runs. CARB 1968.2 requires the battery thermal management outputs to be checked for proper response to commands. No manufacturer publicly documents P0AD1; for fan 1 GM treats an unwanted speed above about 250 rpm with the fan off under its own code P0BC8. Typical causes are a driver stage stuck on or a short to supply voltage. Effects are an audible fan after shutdown and possible 12 V battery drain rather than a drivability problem.
Possible causes
- Fan output stage in battery controller or fan module stuck on high
- Control wire chafed against a supply voltage medium
- Fan relay contacts welded (relay-switched designs) low
Symptoms
- Battery fan audible after the vehicle is switched off
- 12 V battery discharged after standing
- Hybrid or EV warning light
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0AD1
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.