P0AAA
Hybrid/EV Battery Voltage Isolation Sensor Circuit High
P0AAA is the high-side counterpart of P0AA9: the isolation sensor reports a rail-to-ground voltage above anything the pack can produce. GM's tables tie the limit to the pack: over 333 V in the 2016 table and over 416 V in the 2019 table, each in 320 of 400 samples with the bias switch open, Type B, two trips. The 2013 GM table instead flags a mid-pack reading that differs from the motor controller's voltage by more than 15 V. Likely sources are an open reference or ground in the measuring circuit or a failed input stage in the battery controller. No public bulletin from another maker names this code. The car usually stays drivable with warnings, but isolation monitoring is lost, and P0AA6 cannot be trusted until it is fixed.
Possible causes
- Open ground or reference in the isolation measuring circuit high
- Failed isolation input stage in the battery controller medium
- Sense lead shorted to another HV potential inside the pack low
Symptoms
- Check engine and hybrid or EV warning lights
- Isolation monitoring disabled while the code is active
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0AAA
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.