Hybrid/EV Battery Pack Cooling Fan 2 Stuck On
P0A98 reports that battery cooling fan 2 keeps running after the controller has commanded it off; it mirrors P0A83 for fan 1. No manufacturer documents this code publicly. CARB calls for fan outputs to be checked for correct response to commands. GM's published method for fan 1 (sense code P0BC8) flags a fan that still reports more than about 250 rpm after being off for over 20 s; the same logic applies to a second fan. Typical causes are a welded relay, a control wire shorted to supply or fan electronics that ignore the stop command. Cooling is not at risk, but the fan can drain the 12 V battery and is audible after shutdown. Fan 2 circuit codes are P0A96, P0A99 and P0A9A.
Possible causes
- Welded fan 2 relay medium
- Fan 2 control wire shorted to supply medium
- Fan 2 internal controller ignores off command medium
Symptoms
- Battery fan audible after the vehicle is switched off
- 12 V battery discharged after parking
- Hybrid or check engine warning