P0A97
Hybrid/EV Battery Pack Cooling Fan 2 Performance/Stuck Off
P0A97 is the fan 2 counterpart of P0A82: the second battery cooling fan is electrically reachable but does not reach its requested speed or does not turn at all. No manufacturer documents this exact code publicly. CARB requires a functional check of battery cooling where feasible, and the methods are published for fan 1: GM compares commanded and measured speed (its sense code P0BC8), Toyota judges the deviation of the feedback-corrected duty, Honda compares expected and actual battery temperature rise. Blocked air paths and worn motors are the usual causes. Circuit faults on fan 2 are P0A96, P0A99 and P0A9A; the stuck-on case is P0A98. With one fan weak the pack runs warmer.
Possible causes
- Dust or debris on fan 2 or in its duct high
- Worn or seized fan 2 bearings medium
- Blocked air intake to the battery medium
- Faulty speed feedback from fan 2 low
Symptoms
- Hybrid warning or check engine light
- Weak airflow from the battery vents
- Reduced electric assist in warm weather
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0A97
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.