P0A90
Drive Motor A Performance
P0A90 reports that electric drive motor A does not behave as commanded. In GM's eAssist mild hybrid the motor/generator is belt-driven from the crankshaft, so GM uses P0A90 to detect a slipping or broken belt: the motor speed is compared with the engine speed. In 2013 a difference above 1000 rpm for 1.5 s, or repeated smaller slips above 500 rpm on two key cycles, set it; the 2016 tables use more than 1500 rpm for about 5.6 s or repeated 1000 rpm slip events. GM rates it Type A, MIL on the first trip. In full hybrids the generic definition applies to speed or torque deviations of the traction motor. P0A91 is the equivalent for motor B, P0A92 for the generator.
Possible causes
- Slipping, worn or broken drive belt on belt-driven motor/generators high
- Faulty belt tensioner or contamination on the belt medium
- Motor, position sensor or inverter fault in full hybrids medium
Symptoms
- MIL and hybrid system warning
- Belt squeal or auto-stop/start not working
- Reduced electric assist or limp mode
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P0A90
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.