14 Volt Power Module Current Sensor A Circuit High
P0A89 is set when the current sensor of the 14 V power module reports more current than the converter can physically carry. GM's eAssist tables show how: in 2013 the APM input current reading had to exceed 22.5 A for 1.5 s while calculated output power was 1.5 kW or less; in 2016 the limit is 45.25 A or more in 200 of 250 samples (about 5 s) with the APM commanded on and 9 to 32 V supply. Both versions classify it Type B, so the MIL lights after the second failing trip. Typical causes are a signal short to voltage or an internal sensor fault. P0A88 is the low counterpart, P0A87 the in-range plausibility test, and the APM output sensor has its own codes (P0C9E/P0C9F).
Possible causes
- Sensor signal shorted to supply voltage high
- Current sensor in the power module failed medium
- Open sensor ground pulling the signal high low
Symptoms
- MIL and hybrid/charging warning
- Converter output limited, 12 V voltage drops
- Start/stop function may be disabled
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0A89
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?