P0A85
Hybrid/EV Battery Pack Cooling Fan 1 Control Circuit High
The controller detects a short to voltage on the control output of battery cooling fan 1. GM runs the test while the fan is commanded between 11 % and 100 % duty: a circuit voltage above 9 V counts as a failure, and 16 fails in 20 samples set a Type B code with MIL after two trips. GM tables from 2013, 2016, 2018 and 2019 hybrid programs carry it, partly via the output stage status flag. Depending on the circuit, the fan may run constantly at full speed or not respond. The low and open counterparts are P0A84 and P0A81; a fan that keeps running without a circuit fault is P0A83.
Possible causes
- Control wire shorted to a supply voltage high
- Fan control input internally open or shorted to its supply medium
- Corroded connector creating leakage to supply low
Symptoms
- Check engine or hybrid warning after two trips
- Battery fan runs constantly or not at all
- Possible 12 V battery drain when parked
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0A85
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.