P0A81
Hybrid/EV Battery Pack Cooling Fan 1 Control Circuit/Open
The controller watches the output that drives battery cooling fan 1 for an open circuit. In the 2016 GM table the fan is commanded at low duty (under 10 %) and the circuit voltage sits between about 1.6 and 5.85 V instead of being pulled low; 16 failures in 20 samples set it as Type B. An older GM program used it as a general fan unit fault judged by a monitor voltage. Ford found P0A81, often with P0A96 for fan 2, in the battery control module of 2005–12 Escape and Mariner Hybrids and replaced both fans; drivers usually noticed nothing. Low and high faults have their own codes (P0A84, P0A85). Without airflow the pack heats up and power may be limited.
Possible causes
- Fan motor or its internal electronics open high
- Loose or corroded fan connector, broken control wire medium
- Blown fan supply fuse medium
- Faulty output stage in the battery control module low
Symptoms
- Check engine or hybrid warning, often no other complaint
- Battery cooling fan does not run when commanded
- Reduced hybrid power in hot conditions
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0A81
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.