P0A78
Drive Motor A Inverter Performance
P0A78 means the inverter stage feeding drive motor A has reported a power-switch fault. GM explains the check in its hybrid OBD tables: the IGBT module watches each phase for desaturation, a sign of a short between the upper and lower switch; if that status persists for about 2 ms the code sets as Type A, MIL on the first trip. Stellantis replaced the power inverter module on 2021 Jeep Wrangler 4xe with P0A78 and P0A79, which ran on engine power only, and refreshed hybrid control software on the 2017 Pacifica Hybrid. Land Rover logs P0A78 in the inverter converter of 2024-25 Range Rover models and asks not to clear it before diagnosis. P0A79 is motor B, P0A7A the generator inverter, P0A3C overheating of inverter A. Expect a warning and loss of electric drive.
Possible causes
- IGBT desaturation or short in the inverter power stage high
- Power inverter module defective (replaced on Jeep Wrangler 4xe) high
- Hybrid control software requiring update medium
- Shorted winding or phase cable of drive motor A low
Symptoms
- MIL and hybrid or high-voltage warning
- No electric drive, engine-only operation
- Stop safely warning on some models
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0A78
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.