P0A6B
Drive Motor B Phase V Current High
P0A6B is stored when phase V of drive motor B reports more current than the operating state allows. No manufacturer documents P0A6B publicly. Two causes must be told apart: a real overcurrent from a shorted switch, a winding fault or an insulation breakdown, and a sensor that reads high because its gain or zero offset has drifted. Patents show how inverters separate them: Toyota compares a control sensor against a monitoring sensor and the commanded current, Caterpillar checks that the three phase currents still sum to about zero. CARB requires plausibility monitoring of electric drive components. P0A6A is the low side, P0A68 and P0A6E the U and W phases, P0A62 the motor A counterpart. The inverter shuts motor B down to protect itself.
Possible causes
- Phase V current sensor gain or offset drifted high high
- Shorted power switch in the phase V leg medium
- Winding or insulation fault in phase V of motor B medium
Symptoms
- Hybrid warning and MIL
- Motor B cut out, reduced acceleration
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended