Drive Motor B Phase V Current Low
P0A6A is GM's open-circuit test for phase V of drive motor B. The controller checks each phase on its own as the rotor turns; for phase V it looks at the window of 30 degrees either side of the V axis, where the current should be largest. With the inverter above 50 V in normal PWM and a squared current command above 900 A² (2016 Volt) or 4,900 A² (2018 and 2019 tables), a peak below 9 A for 0.4 s out of 0.6 s is a Type A failure with MIL after one trip. The 2016 Volt table describes this motor B code with the words drive motor A, an evident copy slip. A missing V current points to a broken lead, a dead switch or a sensor stuck at zero. P0A6B is the high side, P0A67 and P0A6D phases U and W, P0A61 the motor A code.
Possible causes
- Phase V lead, connector or bolted terminal of motor B open high
- Phase V switch of the motor B inverter not switching medium
- Phase V current sensor output stuck at zero medium
- Open phase V winding in motor B low
Symptoms
- MIL and propulsion system warning after the first trip
- Vibration or uneven torque from motor B before shutdown
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0A6A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?