Generator Position Sensor Circuit Range/Performance
P0A4C means the generator resolver delivers signals that are electrically present but implausible, so the computed rotor angle cannot be trusted. Mitsubishi documents the exact limits for the 2023 Outlander PHEV: the sine or cosine winding voltage must stay between 2.1 and 2.9 V; if either leaves that window for 0.28 s, or an internal status fault persists for 0.31 s, the generator control unit stores P0A4C. Typical triggers are a corroded or loose resolver plug, a chafed shield picking up noise, a winding that has drifted, or a faulty input stage in the power drive unit. P0A4B is the general circuit fault, P0A4D and P0A4E the hard low and high signal, P0A4F a sporadic dropout. Expect a hybrid warning, reduced power and possibly no engine start via the generator.
Possible causes
- Corroded or loose resolver connector high
- Damaged shielding letting interference onto the sine/cosine lines medium
- Resolver winding drifted out of tolerance medium
- Faulty resolver input stage in the power drive unit low
Symptoms
- Hybrid system warning and MIL
- Reduced drive power or engine-only operation
- Engine start via the generator not possible
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0A4C
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?