P0A46
Drive Motor B Position Sensor Circuit Range/Performance
P0A46 reports that the motor B resolver still delivers a signal, but one that is degraded or not plausible. GM uses the same check as P0A40 for its second motor: sine or cosine above 4.0 V, with a failure counted when it persists for 0.2 to 0.4 s of a 2 s window (Type A, one trip in the 2011 and 2016 tables). Mitsubishi (2023 Outlander PHEV rear motor) sets P0A46 when its internal resolver status words A, B or C stay failed for 0.18 s, and replaces the rear motor assembly. A GM-related patent explains the idea: a degraded signal shows as a large mismatch between sine and cosine amplitudes. P0A45 is a full signal loss. Expect a hybrid warning and loss of motor B drive.
Possible causes
- Resolver of motor B delivering unequal or distorted sine/cosine signals high
- High contact resistance or moisture in the resolver connector medium
- Fault inside the rear motor assembly incl. bearing damage (Mitsubishi) medium
- Damaged shielding letting inverter noise into the resolver lines low
Symptoms
- Hybrid system warning and MIL
- Rear or second motor disabled, reduced traction or power
- Jerky torque delivery before the fault sets
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0A46
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.