P0A28
Hybrid/EV Battery Power Off Circuit Low
The control unit watches the voltage on the line that commands the high-voltage battery to disconnect. P0A28 sets when that signal stays below its valid window for a calibrated time, typical of a short to ground or a lost supply on the line. No manufacturer documents P0A28 publicly; GM only lists it as a search keyword in a general pin-fit bulletin. Patents show the power-off path as a hardwired line next to CAN that opens the contactors within milliseconds; CARB requires hybrid components that can affect emissions to be monitored. P0A29 is the opposite fault, P0A27 a mismatch between command and contactor state. Expect a hybrid warning and, depending on strategy, no ready mode.
Possible causes
- Power-off signal line shorted to ground high
- Poor terminal fit or corrosion at the battery or control module connector medium
- Missing supply or blown fuse feeding the power-off circuit medium
- Faulty driver stage in the battery or hybrid control module low
Symptoms
- Hybrid system warning light
- Vehicle does not reach ready mode
- Electric drive disabled, engine runs constantly
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P0A28
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.