P0A27
Hybrid/EV Battery Power Off Circuit
P0A27 covers the circuit that tells the high-voltage battery to drop off the bus, i.e. the command path that opens the main contactors at key-off, after a fault or after a crash signal. Patents describe such a path as a dedicated hardware line in addition to CAN, so the contactors open within milliseconds. The code sets when commanded and actual state disagree. Honda lists P0A27 as High Voltage Contactor Stays Activated on the 2012-15 Civic Hybrid, where it is one of the codes that call for replacing the motor power inverter. P0A28 and P0A29 are the low and high voltage faults of the same line. The driver may see a hybrid warning and the car may refuse to start or power down.
Possible causes
- Contactor or its driver does not release when power-off is commanded high
- Internal fault in the inverter/power unit that controls the contactors (Honda Civic Hybrid) medium
- Damaged wiring or loose terminal on the hardwired power-off line medium
- Crash or emergency shutdown signal stored or still active low
Symptoms
- Hybrid system warning or check engine light
- Vehicle will not enter ready mode or shuts down while driving
- High-voltage system does not power down after key-off
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P0A27
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.