P0A19
Motor Torque Sensor Circuit Low
The control unit watches the voltage of a torque sensor that measures load directly on the traction motor shaft, such as the magnetostrictive sensor in a hollow motor shaft shown in a Honda patent. P0A19 sets when the signal stays below its valid window for a calibrated time, typical of a short to ground, a broken supply or an open signal line pulled low. No manufacturer documents P0A19 publicly; CARB only requires an approved drive motor monitoring plan. P0A20 is the opposite fault, P0A18 a plausible voltage with wrong torque, P0A21 dropouts. The driver usually sees a hybrid warning and reduced electric drive power.
Possible causes
- Sensor signal or supply line shorted to ground high
- Sensor reference or excitation supply missing medium
- Corroded or loose connector at the drive unit medium
- Torque sensor electronics failed, often replaced with the drive unit low
Symptoms
- Hybrid system warning light
- Reduced electric drive power or electric drive disabled
- Engine runs more often, higher fuel consumption
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P0A19
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.