P0A0B
High Voltage System Interlock Circuit A Performance
The interlock loop A responds electrically, but its behaviour does not match what the module expects – for example a loop resistance outside the window, a signal that does not follow the commanded test pattern, or two modules on the same loop disagreeing. Mercedes-Benz logs P0A0B00 in the battery management system, the DC converter and the on-board charger of model line 243 when the vehicle will not start; its listed causes include oxidised interlock pins in the low-voltage connectors, twisted or chafed harnesses and bent pins on HV components. Patent literature explains why voltage-based loops are prone to false alarms from contact resistance and interference. Unlike P0A0C/P0A0D this is not a clear short. Expect the HV system to stay off.
Possible causes
- Oxidised interlock pins in low-voltage connectors raising loop resistance high
- Improperly connected HV connector or bent interlock pins on an HV component medium
- Twisted or chafed interlock harness rubbing on the body medium
- Faulty interlock driver or receiver in a control module low
Symptoms
- Vehicle cannot be started
- High-voltage system warning in the instrument cluster
- Several modules store interlock codes at the same time
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P0A0B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?