P099B
Shift Solenoid G Control Circuit Low
Low-voltage fault, usually a short to ground, in the control circuit of shift solenoid G. Mitsubishi's 2019 service manual for a six-speed automatic uses it for the low-reverse brake shift solenoid: with transmission relay voltage at 2 V or more and the solenoid commanded on, the module sets P099B if the actual voltage stays below 3.7 V for 0.5 s. The check runs continuously; the solenoid is normally energised only in reverse and first-gear coasting. Nissan lists P099B as shift solenoid G in bulletin NTB15-037 for the 2012–2017 Versa, Versa Note and Sentra with the RE0F11A CVT and replaces the control valve when diagnosis confirms it. P099C is the high side, P09A0 the generic open.
Possible causes
- Control wire shorted to ground in harness or connector high
- Shorted solenoid inside the valve body medium
- Transmission control module driver fault low
Symptoms
- Check engine light
- No reverse or no engine braking in first gear (Mitsubishi)
- Limp mode
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P099B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.