P0980
Shift Solenoid C Control Circuit High
High-voltage fault in the control circuit of shift solenoid C, meaning a short to supply. GM documents it for the Allison 1000 six-speed: the 2007 table wants four consecutive power-short samples (100 ms, Type A) and skips the check in reverse trim, 5th and 6th gear; later tables (2016, 2018) look for 0.39 ohm or less to a supply over three counts within 75 ms, and from 2022 within 60 ms, MIL after one trip. Ford uses it for SSC short to power in all its listed gearboxes, with P0760 for an open. Neither GM's 6L/6T six-speeds nor Saab's documented gearboxes use P0980. The ground counterpart is P0979, the open code for the Allison is P097C.
Possible causes
- Solenoid C control wire shorted to a supply voltage high
- Shorted turns in solenoid C lowering its resistance medium
- Adjacent pins bridged by fluid or debris in the connector medium
- Faulty driver stage in the control module low
Symptoms
- MIL on after the first faulty trip
- Solenoid C stuck energized, wrong gear or default gear
- Harsh shifts
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P0980
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.