P097A
Shift Solenoid A Control Circuit/Open
Open-circuit fault in the drive circuit of shift solenoid A, a code that later J2012 editions added; older lists still show P097A as reserved. GM is the only maker found that documents it: the 2022 to 2025 tables for the Allison 1000 six-speed in its heavy-duty trucks call it Shift Solenoid 1 Control Circuit Open. After one hardware fault the module flags pending, and after three samples it opens the low-side driver as a test; three more open readings at 9 to 18 V set the code (120 ms, MIL after one trip). The same gearbox once used P0972 for this and P0973 in 2016. Ford reports an open SSA as P0750, GM six-speeds as P0974, and Genesis folds all electrical faults of A into P0753.
Possible causes
- Open coil of shift solenoid 1/A high
- Unplugged, corroded or pushed-out pin at the transmission connector high
- Broken wire in the internal or external transmission harness medium
- Faulty low-side driver in the control module low
Symptoms
- MIL on after one faulty trip
- Transmission in a fixed default gear
- Shifts involving solenoid A missing
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P097A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.