P0913
Gate Select Actuator Circuit High
Set when the drive circuit of the gate select actuator of an automated manual gearbox shows a voltage that is too high for the current switching state. Usual causes are a short of a motor or control line to battery voltage, or a driver stage in the module that no longer switches off; depending on the circuit design an open load can also read high. No manufacturer documents this code publicly. Patents by Isuzu and Hyundai/Kia describe electric select and shift actuators that the transmission controller powers directly, and CARB requires circuit checks on such outputs. P0912 is the opposite low fault, P0910 the open circuit, P0911 the plausibility fault and P0909 a select movement that misses its gate. The driver sees a warning lamp and a gearbox that can no longer change gates.
Possible causes
- Actuator wire shorted to battery voltage high
- Open motor winding read as high voltage by the driver stage medium
- Driver stage in the transmission control module stuck on low
Symptoms
- Check engine or transmission warning light on
- Gearbox stops changing gates or holds one gear
- Actuator may run noisily or get hot
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P0913
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.