P0905
Gate Select Position Circuit A Range/Performance
Plausibility fault of the gate select position signal on circuit A in an automated manual gearbox. The signal is electrically within limits, but it does not fit what the control module expects: typical checks compare the measured select travel with the learned gate positions and the commanded target gate. No manufacturer documents this code in freely citable material. Patents by Aisin AI on select control with target and actual gate, and on fallback strategies after a stroke sensor failure, show how the module depends on this signal; CARB requires rationality checks on such inputs. P0904, P0906 and P0907 cover the electrical faults, P0909 a select movement that misses its target. The driver typically sees a fallback mode with no or limited shifting.
Possible causes
- Worn or drifting gate select sensor, main and redundant tracks disagree high
- High resistance at connector pins distorting the sensor voltage medium
- Gate positions not relearned after actuator, clutch or TCM replacement medium
- Loose or displaced magnet or sensor mounting on the select shaft low
Symptoms
- Check engine or transmission warning light on
- Gearbox drops to neutral or refuses certain gears
- Slow or jerky gear changes in fallback mode
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P0905
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.