P0828
Up and Down Shift Switch Circuit High
Many selectors read tap-up and tap-down over one shared wire with voltage steps or a resistor network; P0826–P0828 cover this shared circuit, P0815/P0816 the single directions. P0828 means the shared circuit voltage is too high – a short to positive, or on ground-switching switches with a pull-up also an open. No manufacturer document available to us uses it: Saab's 9-3 Sentronic reports this state as P0826 (above 6.7 V for more than 30 s), Saab's 9-4X as P0815 or P0816, and GM as P0826. Manual shifting would be disabled while automatic operation stays normal.
Possible causes
- Signal wire shorted to positive high
- Signal wire or selector ground open (pulled-up input) medium
- Selector assembly faulty medium
- Control module low
Symptoms
- Tap or manual shifting not working
- Transmission warning in the cluster
- No effect on driving in automatic mode
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P0828
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 4 affected components(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.