P06EF
Engine Restart Performance
P06EF concerns the automatic restart after the system itself has stopped the engine – stop-start or hybrid. The restart, by starter, reinforced stop-start starter or belt starter-generator, takes too long or fails. CARB does not count such a commanded shutdown as a stall. No manufacturer publishes the time limit. VW's Tiguan bulletins list P06EF together with P06E9 and trace both to dirt inside the starter; FCA fixes it on the 2019 Jeep Wrangler with engine-module software and lights the check engine light. Stop-start is then disabled. Besides the starter, a weak stop-start battery or fuel and ignition problems at restart can be the cause.
Possible causes
- Starter or starter-generator worn, contacts intermittently open high
- Engine module software medium
- Weak stop-start battery (AGM/EFB) or battery sensor medium
- Fuel pressure or ignition at restart low
Symptoms
- Engine does not restart or restarts late after stop-start
- Stop-start disabled
- Check engine light (FCA)
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P06EF
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 4 affected components(visible in Pro mode)
- 1 warning for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.