P064E
Internal Control Module O2 Sensor Processor Performance Bank 2
An internal self-test in the control module reports a fault in its processing of the "oxygen sensor processing, bank 2" value. The module computes and cross-checks this value redundantly inside its own processor; when the results disagree, the code sets. It points to a hardware or software fault inside the module itself, not to a defect of the external sensor. Causes are an internal processor or memory fault, corrupted control-module software, or low or disturbed module supply voltage.
Possible causes
- Internal software anomaly high
- Module software outdated, reflash may resolve low
- Supply voltage outside specification low
Symptoms
- Check engine light on
- Increased fuel consumption
- Possible rough idle or hesitation
- Failed emissions test
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
- Estimated cost: 400–2500 €
- Estimated time: 2–8 h
- Component: ecu internal processing
- Component: oxygen sensor b2
- MIL / check engine light
- emissions-relevant